Mcquay model number tonnage

R-123 requires about 6 times the gas flow rate (cfm/ton) of R- 134a, which means that the suction and discharge piping must also be six times larger. Using R-134a allows McQuay to provide you with a smaller footprint chiller. Table 1: Centrifugal Models & Possible Applications Application McQuay Model

Mcquay model number tonnage. General Directions: (1) Locate the model number your researching. (2) Hover over each grouping to reveal pertinent info for each part of the model number. (Note: Tonnage, Air Flow, kW, etc. are located within the oval/round shaped buttons). Thank-You For Sharing. 4CX*** Unit Nomenclature.

Basically all manufacturers encode the size or tonnage of their systems into the model number. Tonnage is a measure of BTU’s in 12,000 BTU increments. For example a 1 ton system would have 12,000 BTU’s. A 2.5 ton system would have 30,000 BTU’s. These are reflected in the model numbers near the middle and often followed by a letter.

The date of production/manufacture or age of AAF brand HVAC equipment can be determined from the serial number located on the data plate. Note: Traditional heating and cooling systems no longer manufactured under AAF or AAF-McQuay brand names. Parent Company: AAF International and AAF-Flanders, a subsidiary company of …This supplement only applies to RGS180 units when there is "B" in the 9th position of the Model Number, as shown in the Model Number Nomenclature diagram below. Check the Unit Nameplate (see Figs. 1 & 2). If there is not a "B" in the 9th position of the model number discard this document. MODEL NOMENCLATURE MODEL SERIES R G S 1 8 0 H F ...Quiet, 3-speed permanent split capacitor motor. High performance forward curved centrifugal fan wheels. Split design fan housings or single-piece fan housings with separate inlets for exceptional serviceability. Single power location for field wiring connections in unit elec-trical box.Chillers. At LEL International, we ensure that you have access to a wide variety of new and used industrial chillers for sale, allowing you to find the one that best meets your needs. Our HVAC chillers can provide the appropriate temperature, humidity, and ventilation for structures of any size or nature. Whether you are seeking heat management ...McQuay Water Cooled Chiller, year 1988, Model WHR070D, S/N 5TD0189100, 460 volt, 70 ton, 2 compressors.For Assistance: Give A Missed Call: @ 9210188999 Call Our Customer Support: 011-40319300 / 1860 180 3900 or Write To Us at: [email protected] For Refrigeration Products:

McQUAY CENTRIFUGAL OPERATING LOG. .23 McQUAY SERVICE PROGRAMS 24.17, 18 18 18 18 18 18 19 19 INTRODUCTION GENERAL DESCRIPTION The McQuay Model PEH Centrifugal Water Chillers are com-plete, self-contained, automatically controlled water chilling units. Each unit is completely assembled and factory tested prior to shipment.How to determine the date of production/manufacture or age of Daikin® brand HVAC Systems. The industry average service design life for most forced air furnaces is 15-20 years, and the industry average service design life for most air conditioning condensing units is 10-15 years. The average service design life of boilers can vary from as ...The optimum model can be selected from an extensive product lineup for medium- to large-scale facilities for use in a variety of applications. Versatility. Daikin delivers energy efficiency to a wide range of process cooling applications with a lineup featuring a full range of capacities for all conditions and cooling requirements. ... Basically all manufacturers encode the size or tonnage of their systems into the model number. Tonnage is a measure of BTU’s in 12,000 BTU increments. For example a 1 ton system would have 12,000 BTU’s. A 2.5 ton system would have 30,000 BTU’s. These are reflected in the model numbers near the middle and often followed by a letter. All McQuay low and medium pressure central station air handling units (sizes 114 through 172) have factory installed, internally mounted motors and drives .. This means that ex­ pensive jobsite coordination and field mounting of motors has been eliminated .. Motor life is increased with the McQuay air handling unitsMcQuay was founded in the United States in 1933 and has been supplying and servicing equipment for air conditioning, heating and ventilation systems, as well as manufacturing radiators and heat exchangers. ... I also don't have the full model number on the sticker so its difficult to find. Anything will help thank you! chad M/N - LCA150 SM S/N ...McQuay R-410A condensing units are available with EERs that exceed ASHRAE 90.1-2004. R-407C inevitably forces the unit to be significantly less efficient or more expensive, while R-410A reduces energy costs. R-410A refrigerant components are always evenly mixed, which is not true for R-407C.

View and Download McQuay ALR 110F product manual online. Air-Cooled Reciprocating Water Chillers, 110 to 150 Tons, 380 to 525 kW, R-22, 60 Hertz. ALR 110F chiller pdf manual download. Also for: Alr 120f, Alr 140f, Alr 130f, Alr 135f, Alr 145f, Alr 150f.1994 McQuay Water-Cooled Chiller- 320 Ton. Model: PEH079. S/N: 5ZE81006-00. Style: 9572513010. Liquid chiller; self-contained unit. R-134a only. Compressor hours: 9812; compressor starts: 1814. Overall dimensions for chiller: 234.5 in. L x 46 in. W x 72 in. H. This unit was the East Campus Chiller running two dorms atMfr: Daikin Mcquay; Mfr Part #: 01EC-9021; PT #: Parts Town #: DAKM01EC-9021; Third-Party Seller; Something went wrong. Please try again. Temporarily unavailable. Daikin Mcquay 047356110K HIGH PRESSURE CONTROL KIT ... This item requires a Model & Serial Number to purchase. Type Model.MCQUAY MODEL NUMBER LOOKUP - SOSTENESCAVALCANTE.COM.BR. Large selection of McQuay parts. mcquay model number description 2_| Documentine.com Model number on the back cover: A1456, A1507, A1516, A1529, A1532. ... FIND TONNAGE ON AHU NOMENCLATURE QUALITY HVAC INFO 101 ...

How to get into the pond lab grounded.

Model AGZ-E • 30 - 70 RT Model AGZ-D • 75 - 190 RT Remote Evaporator and Pump Package options available AGZ-D A M AGZ-E. 4 CAT 624-1 Features and Benefits Chiller Nomenclature Features and BenefitsUnit Design Features Daikin AGZ air-cooled chillers are a product of our commitment to offer quiet, reliable, energy efficient ...Accessory description Model number Sizes used on Anti-short cycle timer kit RXAT-A01 All Sight glass RXAG-A048 6.5 - 15 ton Sight glass RXAG-A020 20 ton Thermostat Terminals (Upper) L PH D SA SB SC OT Malfunction Light X-10 Module Input Not Used Remote Sense A Remote Sense B Remote Sense C Outdoor Sensor Thermostat Terminals (Lower)SALES. [email protected]. 817-229-3171. North Texas Office: Dan @ 817-966-5350. South Texas Office: Mike @ 210-413-3333. This Used MCQUAY 50 Ton Water Cooled Chiller has been inspected and is located in our facility in Bridgeport, Tx. We Buy and We Sell New and Used Chillers, Cooling Towers and Equipment.Troubleshooting Refrigeration Circuit. 25. Typical Refrigeration Cycles. 26. General Maintenance. 27. Advertisement. Mcquay Enfinity CCH series Pdf User Manuals. View online or download Mcquay Enfinity CCH series Installation & Maintenance Data.McQuay Air Handlers MCW 800 H Instruction manual (41 pages) 18. McQuay MCW 200 C. McQuay Air Handlers MCW 200 C Instruction manual (41 pages) 19. McQuay Vision CA Series. McQuay Air Handlers Vision CA Series Installation and maintenance manual (36 pages) 20. McQuay MDM-1826 Series.McQuay 61149604 HEATER ELECTRIC WIRE. Our Price: C$ 172.78. My Price: Mfr Part #: 61149604. PT #: MCQ061149604. Quantity Available: 0. Out of Stock, backorders usually ship in 10-12 days. Add to cart. Add to My Parts.

These links wiIl lead to yóu purchase a próduct from another cómpany. Mcquay Chiller Model Numbers Serial Numbers And How Question Posted By Francisco the Building Engineer on May 3, 2011 Refer to the manufacturers website for their HVAC nomenclature of the model number and serial numbers and how those numbers …Used 22 ton McQuay chiller, model ALR022C, air cooled, R22 refrigerant, 25 hp compressor, air cooled, 460 volt, serial# 5ZC8505602, built 1994. Today, McQuay possesses more than 13 manufacturing plants occupying some 200,000 square meters on three continents; North America, Europe and Asia together with sales and service offices in 75 countries. With a diligent workforce of over 15,000, McQuay is dedicated to producing the best quality equipment in the air conditioning industry. York/Quantech – Johnson Controls. Our literature library of data sheets, manuals, & engineering specs is constantly growing. If you need finding product literature call us at 214-321-4200.burner model number, minimum/maximum input, maximum temperature rise, and minimum CFM. On units that utili ze the tandem scroll compressor design, each compressor includes an individual nameplate along with a nameplate identifying the tandem compressors. On units that utilize the tandem reciprocating design, eachIf you are in the market for a new microwave, you may have come across various model numbers from GE. Understanding these model numbers can help you make an informed decision and f...48TC UNITS MODEL NUMBER NOMENCLATURE Model Series - WeatherMaker ® TC - Standard Efficiency Unit Heat Type 48 - Gas Heat Packaged Rooftop Cooling Tons (Vertical Airflow) 17 = 15 tons 28 = 25 tons 20 = 17.5 tons 30 = 27.5 tons 24 = 20 tons Heat Options D = Low Gas Heat E = Medium Gas Heat F = High Gas Heat S = Low Heat w/ Stainless Steel ExchangerModel: The Unit Model Number: Note- It is very important to remember that the AAF and HermanNelson model numbers differ from all the other brand names listed in the index in that the model number is located in the middle of the alpha/numeric model number string. (Example: SPAGAAPFCWG53211000. The bold letters indicate the model number.Page 1 Installation, Operation, IOM 1210-1 and Maintenance Manual Group: Chiller Part Number: IOM1210-1 Date: August 2014 Magnitude ® Magnetic Bearing Centrifugal Chillers Model WMC, C Vintage 125 to 400 Tons (440 to 1400 kW) HFC-134a Refrigerant 50/60 Hz...; Page 2: Table Of Contents ©2014 Daikin Applied. Illustrations and data cover the …technology and quiet operation. Model AGS units utilize a new compressor design utilizing R-134a refrigerant. Superior control is used with the MicroTech II® family of controllers with Open Choices™. They continues McQuay’s position of being the only air-cooled screw compressor chiller with superior solid state starters as standard equipment.The number is divisible by 6 or 12 and refers to the nominal BTY of the system in thousands. A ton of air conditioning is equivalent to 12,000BTU, and 30 divided by 12 is 2.5. Therefore, the data plate below refers to a system in 2-1/2 tons. Here's a list of the range to expect with American Standard AC units: 18 = 1.5 tons.

Goodman air conditioning unit tonnage can be determined by the unit’s model number. This number is located on a plate attached to the back of the unit, near the power supply and co...

Part Number: 668996503. Date: November 2011. IM 930-3 ©2011 McQuay International ® Page 2 of 32 / IM 930-3. Model Nomenclature Vertical Floor Unit (Size *007 - 070) NOTE: For illustration purposes only. Not all options available with all models. Please consult McQuay Sales Representative for specific availability.Chiller Details. 1998 McQuay Air Cooled Liquid Chiller. Model: ALS125AS27. Rated capacity: 125 tons. Refrigerant: R-22. Maximum relief pressure: 450 psig. Design pressure hi/lo: 450/150 psig. System requirements: 460 V, 274 amps, 60 Hz, 3 phase. (2) McQuay Screw Compressors, Models: SAL155QA10DA and SAL155QA10DA, 380/460 V, 461/489 LRA.Gives number of compressors in unit. Thirteenth Digit Type of Heat: B. Hot water Boiler w/ Cooling C. Cooling Only D. Gas Duct Furnace E. Electric Heater F. Direct Fired Gas Burner H. Hot Water Coil M. High Turndown Power Burner P. Power Burner S. Steam Coil T. Tubular Gas Heater X. None Fourteenth Digit Heating Medium N. Natural Gas O. Oil P ...One essential piece of information is the model number. This alphanumeric code holds the secret to figuring out the size of your system. ... Model Number Tonnage; 18: 1.5: 24: 2: 30: 2.5: 36: 3: 42: 3.5: 48: 4: 60: 5: This table provides a clear breakdown of the model numbers and their corresponding tonnage values for your Heil air conditioners ...Any reliance you place on such information is therefore strictly at your own risk. David Stewart. Hours:(Daily) 7AM-9PM. Telephone:(208) 758-5570. Email: …Low installation and operating costs. Plenum fans allow quieter operation. Modular construction from 20 to 130 tons. Controls flexibility—MicroTech® III controls for easy integration with the BAS of your choice. R-410A refrigerant allows higher efficiency (model SWP only) A self-contained AC unit from Daikin is an ideal option for multi ...A number model is a sentence that shows how a series of numbers are related. An example of a basic number model could be 12+3=15. A number model is an equation that incorporates ad...Daikin offers a wide range of condensing units from 6 to 140 tons with a full range of options to meet efficiency, performance or serviceability requirements. Our model RCS condensing unit meets ASHRAE 90.1 2010 efficiencies, uses scroll compressors for reliability, offers optional condenser fans for quiet operation, and provides low ambient ...

European wax center orlando reviews.

Grantsville foodland.

That would be a 50ton Roof Top Unit or RTU. It has DX cooling, that is Direct Expansion or simply the Refrigerant cools the air, opposed to a CW unit that has Chilled Water to cool the air. Reply. 07-31-2012, 06:26 AM #5. beenthere.MODEL NOMENCLATURE Table 1: Unit Nameplate Model Number Identifier Model AHP = Air Cooled Heat Pump Nominal Capacity (tons) 090 = 7-1/2 120 = 10 Future Use Voltage/Phase P = 208-230/3/60 Q = 460/3/60 EER E = 10.1 Vintage AHP 090 A PEY Unit Nameplate McQuay Model Number CPLE090-3C AHP090APEY CPLE090-4C AHP090AQEY CPLE120-3C AHP120APEY CPLE120-4C ...Page 76 McQuay Training and Development Now that you have made an investment in modern, efficient McQuay equipment, its care should be a high priority. For training information on all McQuay HVAC products, please visit us at www.mcquay.com and click on training, or call 540-248-9646 and ask for the Training Department.The Raspberry Pi Foundation released a new model of the Raspberry Pi today. Dubbed the A+, this one's just $20, has more GPIO, a Micro SD slot, and is a lot smaller than the previo...Daikin RoofPak applied packaged rooftop systems, from 15 to 150 tons, are the ideal solution for your one to eight-story building projects. Available in air-cooled and evaporative-cooled models, they combine the lower installation costs and interior space savings of a roof-mounted system with the operating and maintenance efficiencies of ...Model Number Notes 1. Available on 3-5 ton models. 2. Standard on 4-5Ton E3,4,W and 6-10Ton Heat Pumps and all High Efficiency models. 3. Not available with electromechanical controls. 4. Manual outside air damper will ship factory supplied within the unit, but must be field installed. 5. Highpressurecontrolisstandard on all units. 6. On 3-5 ...McQuay Central Air Conditioner. Metal Grille & Universal Design. More convenient for market stocks and spare part stocks. High Efficiency Compressor. Low levels of electricity consumption. Universal Communication. 24V universal communication connection, safe and simple. Multiprotection. High & low pressure protection.We take no part in the refund and exchange of equipment and material sold here unless product model number, serial number are not identified in sales agreement executed. ... 180 Ton McQuay Air Cooled Chiller(s) $ 19,500.00 $ 19,500.00 Read more; 30 Ton Carrier Chiller - Surplus inventoryMcQuay International Re-Manufactured Screw Compressor. Model: SAL155QA10DA. Capacity: 60 tons using Freon, only. ... 60 Ton. Sold Out. Roll over image to Zoom OR Click for full Gallery (images, video, data sheets) ... McQuay; Model: SAL155QA10DA; Serial Number: 55GR7061-10; Package Details. Screw Compressor Details. Micro Panel Details. ….

It'll look like the image below. Up near the top of the label, you see the model number (M/N) and serial number (S/N). The model number is where you can find the number you're looking for. Not all manufacturers do this, but most will give you a 2 or 3 digit section that tells you how many thousands of BTU/hour your air conditioner can move ...Page 26 / Catalog 770-14. Unit Sizes S10 & S12 (1000 thru 1200 cfm) Furnish and install where shown on plans McQuay high cfm design HiLine Fan Coil units. Unit sizes, performance and equipment shall be as tabulated in the schedule. Unit performance shall be substantiated by computer generated output data.Compressor Stage 1. Cooling Capacity 56000. Family Comfort. Gas Stages 1-Stage. Nominal Seer 16. Refrigerant R410A. Tonnage 5. Voltage (Phase) 208/230 V 1-Phase. Air Flow Vertical.The 30HXC units are freshwater- or seawater-cooled chillers, designed from the ground up to meet the needs of today and tomorrow: Non-ozone depleting HFC-134a refrigerant. Screw compressors. Fits through narrow access doors without disassembly. Mechanically cleanable evaporators and condensers. Wide range of marine & offshore customizations.SALES Hunter: 713-851-7576 Jamey: 214-755-8019 . Para Español: 214-321-4200Quiet, 3-speed permanent split capacitor motor. High performance forward curved centrifugal fan wheels. Split design fan housings or single-piece fan housings with separate inlets for exceptional serviceability. Single power …SALES. [email protected]. 817-229-3171. North Texas Office: Dan @ 817-966-5350. South Texas Office: Mike @ 210-413-3333. This Used MCQUAY 50 Ton Water Cooled Chiller has been inspected and is located in our facility in Bridgeport, Tx. We Buy and We Sell New and Used Chillers, Cooling Towers and Equipment.You should see a model number and a string of numerals and letters. There should also be an even, two-digit number – which indicates the AC tonnage of the unit. This number is typically between 18 and 60. Divide this number by 12 (representing 12,000 BTU/hr, or one ton of cooling capacity) to get the overall tonnage of the unit. Mcquay model number tonnage, Find the most common problems that can cause a Mcquay Air Conditioner not to work - and the parts & instructions to fix them. Free repair advice! En español. 1-800-269-2609 24/7. Track Order. ... Need help finding your model number? or. Let Us Diagnose The Problem. Select “Common Problems” below and we’ll help you discover the cause of ..., The subbase for the Suite II series hydronic heat model is 8" high with a front air intake grille. Leveling legs are supplied with each subbase that allow for an additional 1" adjustment. The standard subbase requires a minimum of 4-3 /8" from the front edge of the wall sleeve to the finished wall., 1998 McQuay Air Cooled Chiller - 204 Ton Mfg: McQuay Model: ALS204AS12 Stock No. PSL01.15 Serial No. 58G8128101 1998 McQuay Air Cooled Liquid Chiller- 204 Ton. Model: ALS204AS12. S/N: 58G8128101. Refrigerant: R-22. Maximum relief pressure: 450 psig. Design pressure hi/lo: 450/150 psig. System requirements: 208 V, 881 amps, 60 Hz, 3 phase., The label/tag has faded all I have on file is the model number and the serial number, make. Question Posted By Francisco the Building Engineer on May 3, 2011. Refer to the manufacturer's website for their HVAC nomenclature of the model number and serial numbers and how those numbers correspond to the tonnage and other technical data., All fields. description: 2004 McQuay Air Cooled Chiller 130 Ton. Model AGZ-130BS. S/N STNE04109521, 460 /60/3. This chiller is factory new used only for in house testing. Has 6 scroll compressors and is capable of producing glycol at 0 F. name: 2004 McQuay Air Cooled Chiller 130 Ton Model AGZ-130BS. From genemco.com, Model: The Unit Model Number: Note- It is very important to remember that the AAF and HermanNelson model numbers differ from all the other brand names listed in the index in that the model number is located in the middle of the alpha/numeric model number string. (Example: SPAGAAPFCWG53211000. The bold letters indicate the model number., The McQuay RoofPak air handling unit arrives on the job site fully assembled and factory tested ready for start-up. An ... labeled and all wiring is color and number coded. A large, Catalog 206 / Page 5 The available MicroTech controller on the RDS 800C and 802C provides complete temperature control and, if re-, All fields. description: 2004 McQuay Air Cooled Chiller 130 Ton. Model AGZ-130BS. S/N STNE04109521, 460 /60/3. This chiller is factory new used only for in house testing. Has 6 scroll compressors and is capable of producing glycol at 0 F. name: 2004 McQuay Air Cooled Chiller 130 Ton Model AGZ-130BS. From genemco.com, McQuay was founded in the United States in 1933 and has been supplying and servicing equipment for air conditioning, heating and ventilation systems, as well as manufacturing radiators and heat exchangers. ... I also don't have the full model number on the sticker so its difficult to find. Anything will help thank you! chad M/N - LCA150 SM S/N ..., A ton of air conditioning equals 12,000 BTU's so, for example a "24" in the middle of the model number indicates that it is a 2-ton system, a "30" means 2-1/2 tons, and the "42" in the middle of the model number at the top of the page means the system is 3-1/2 tons. Here's a few more examples: Trane - 4TWR3030A1000AA - 2-1/2 tons, Install a tee fitting with a leak-tight removable cap in each tube near the sensor fitting. This facilitates connecting a manometer or pressure gauge if testing is required. Use different colored tubing for the duct pressure (HI) and reference pressure (LO) taps, or tag the tubes. McQuay recommends 1/8" ID tubing., 1996 McQuay Air Cooled Screw Chiller 200 Ton. Model: ALS204A27. Rated at 204 tons using R-22. (2) McQuay Screw Compressor model no.'s: SAL175RA13DA. McQuay Chiller Barrel Model no. E 2010. Refrigeration side MAWP: 225 psi @ 109°F, MDMT: 20°F at 225 psi. ... Model: ALS204A27; Serial Number: 56F8139401; Chiller Details. Air Cooled or Liquid ..., Unit Model Number- Dataplate Unit Type: AWS= Air- Cooled Screw Compressor Chiller Nominal Tonnage ex. 300= 300 Tons Vintage Number of Compressors (circuits) D= 2 …, Features. Stable operation with entering condenser water temperatures 30°F (16.7°C) below leaving chilled water set point. Offers exceptional efficiency with below 0.100 kW/ton at part load. Less complex magnetic-bearing technology for superior reliability and performance compared to refrigerant-lubricated, ceramic ball bearings., Specific Inspection Topics Inspecting HVAC Systems. mbruchs (Michael Bruchs) August 6, 2014, 3:17am 1. Inspected a 1967 condominium with a McQuay Inc air handler (manufactured in Minneapolis), model number SVD-81-U with serial number V 110, used for both cooling and heating. The cooling system was functional during the inspection., The tonnage of an AC unit can typically be determined from the model number by looking for a number that is divisible by 12. For example, if the model number is ABC12345, and the number 36 appears in the middle of the model number (e.g., ABC36 12345), then the AC unit is likely a 3-ton unit, since 36 is divisible by 12., General Directions: (1) Locate the model number your researching. (2) Hover over each grouping to reveal pertinent info for each part of the model number. (Note: Tonnage, Air Flow, kW, etc. are located within the oval/round shaped buttons). Thank-You For Sharing. ACNF** Unit Nomenclature., General Directions: (1) Locate the model number your researching. (2) Hover over each grouping to reveal pertinent info for each part of the model number. (Note: Tonnage, Air Flow, kW, etc. are located within the oval/round shaped buttons). Thank-You For Sharing. H3 Series Unit Nomenclature., The date of production/manufacture or age of AAF brand HVAC equipment can be determined from the serial number located on the data plate. Note: Traditional heating and cooling systems no longer manufactured under AAF or AAF-McQuay brand names. Parent Company: AAF International and AAF-Flanders, a subsidiary company of …, Page 11: Changed Part Number note to "These Parts are ordered per Code Item on original G.O. Contact McQuay Parts with model and serial number information" Page 12: Added . LSB Motor Location Diagram. section. Page 15: Changed footnote #1 to "Obsolete and no longer available. Contact McQuay Parts for more information." Page 21, 22: Added, Part Number: 910131165. Date: May 2012. IM 1049-3. Daikin McQuay ® Enfinity ™ Horizontal Water Source Heat Pumps R-410A Refrigerant. Model CCH, CCW Unit Sizes 007 – 070 ©2012 McQuay International • 800.432.1342 • www.daikinmcquay.com , Installation and Maintenance Manual. M5WM Wall Mounted Split Type Air Conditioner (SEER 13) Indoor Unit. Outdoor Unit. IM-5WMF (SEER13)-0706-McQuay. Group: Wall Mounted. Part Number: R08019028218. Date: July 2006. Wireless Remote., Accessory description Model number Sizes used on Anti-short cycle timer kit RXAT-A01 All Sight glass RXAG-A048 6.5 - 15 ton Sight glass RXAG-A020 20 ton Liquid line solenoid valve RXAV-BD048 All Suction line service valve RXMV-AC 6.5 and 7.5 ton Suction line service valve RXMV-AD 10 and 12 ton Suction line service valve RXMV-AE 15 and 20 ton, In today’s fast-paced world, having a reliable and efficient microwave in your kitchen is a necessity. When it comes to choosing the right microwave for your needs, GE is a brand t..., Daikin Applied, Page 1 Centrifugal Compressor Water Chillers THE DISTINCTION SERIES ™ ™ Model WDC, Dual Compressor, 160 to 2700 Tons (560 to 9500 kW) Model WSC ... Impeller from a McQuay single stage 300 ton (1050 kW) compressor; diameter = 6.3 in. (16 cm), weight = 3.0 lb (1.4 kg) Right: One of three impellers from a 300 ton HCFC-123 compressor; diameter ..., McQuay was founded in the United States in 1933 and has been supplying and servicing equipment for air conditioning, heating and ventilation systems, as well as manufacturing radiators and heat exchangers. ... I also don't have the full model number on the sticker so its difficult to find. Anything will help thank you! chad M/N - LCA150 SM S/N ..., General Directions: (1) Locate the model number your researching. (2) Hover over each grouping to reveal pertinent info for each part of the model number. (Note: Tonnage, Air Flow, kW, etc. are located within the oval/round shaped buttons)., Model: The Unit Model Number: Note- It is very important to remember that the AAF and HermanNelson model numbers differ from all the other brand names listed in the index in that the model number is located in the middle of the alpha/numeric model number string. (Example: SPAGAAPFCWG53211000. The bold letters indicate the model number. , McQuay Offers the Widest Choice of ARI Certified, Ozone Safe Centrifugal Chillers NOTE: The upper capacity limit for ARI certification for water-cooled chillers is 2,500 tons. …, Used 22 ton McQuay chiller, model ALR022C, air cooled, R22 refrigerant, 25 hp compressor, air cooled, 460 volt, serial# 5ZC8505602, built 1994. Request More Information from Seller See Listing on Dealer's Website, Replacement Parts List No Revision L 05/2016 McQuay Seasonmaker Thinline TM Vertical Fan Coil TSF, TSB Sizes Vintage E FTSF, FTSS, FTSB, FTPF Sizes S02 - S12 Designs: A(1) & B(2) To ... 6 Nomenclature Continued Complete Unit Model Number- Current FTPF 2 S02 J A 70 E 28 AS 16 Z I C 1 Code 0 1 & & 02 Unit Model FTPF= Vertical ThinLine TM w/tamper ..., 1998 McQuay Air Cooled Liquid Chiller. Model: ALS125AS27. Rated capacity: 125 tons. Refrigerant: R-22. Maximum relief pressure: 450 psig. Design pressure hi/lo: 450/150 psig. System requirements: 460 V, 274 amps, 60 Hz, 3 phase. (2) McQuay Screw Compressors, Models: SAL155QA10DA and SAL155QA10DA, 380/460 V, 461/489 LRA