Running pressures for 410a

Digital Fieldpiece Gauges: https://amzn.to/2LFjNnKR410A Equipment: https://amzn.to/2xv6AG5My Favorite Tool: https://amzn.to/3NIFJuOTools We Recommend: https:...

Running pressures for 410a. Break the vacuum on the system and supply liquid R-410A to the liquid line or receiver port. Weigh in the initial charge and ensure a proper vacuum was achieved. Adjust sensors or set points to operate the compressor continuously while charging the system. Add refrigerant to allow the discharge pressure to rise to 325-420 psig.

Published on May 26, 2019Background image from pixabay.comMusic provided by NCS. NCS Spotify http://spoti.fi/NCS SoundCloud http://soundcloud.com/nocopyr...

However, R-410A does have higher pressure and can become combustible when mixed with air. 0905_401A_7Tips_020_023 10/20/05 10:50 AM Page 21. ically shipped and stored in cylinders at 830 psig. When R-410A is stored ... Chestnut Run Plaza, Bldg. 702 4417 Lancaster Pike Wilmington, DE 19805 Tel: 1-800-235-7882 www.refrigerants.dupont.comThe pressure of R-410A is so high that if your hand gets in the way of a leak, it could cut a finger off. This is a myth, as well as a physical impossibility. Devices such as insulin jet injectors require 7,000 to 10,000 psi pressures to puncture the skin and 16,000 to 25,000 psi pressure spikes are normally used. R-410A does exhibit pressures ...18 Sept 2020 ... When your compressor has both a low head pressure and a high suction pressure your refrigeration equipment is still running, but the temperature ...Warning: Do not attempt to troubleshoot refrigerant charge on central air conditioning units unless you are EPA 608 type II Certified. This article refers to troubleshooting refrigerant charge on 410a and R22 residential air conditioning systems. Although many of the principles will carry over to other types of refrigerants and drop-ins. I will be sharing a …R-410A, sold under the trademarked names AZ-20, EcoFluor R410, Forane 410A, Genetron R410A, Puron, and Suva 410A, is a zeotropic but near-azeotropic mixture of difluoromethane (CH 2 F 2, called R-32) and pentafluoroethane (CHF 2 CF 3, called R-125) that is used as a refrigerant in air conditioning and heat pump applications. R-410A cylinders were colored rose but are no longer specially color ...The equal pressures when running can be caused by having manifold wheels open by mistake. That's not the case here is it? ... So, I decided too and some 410a. The pressures before energizing the unit were 170 lbs. on both sides. Upon energizing the unit the operating pressures were 75lbs on suction side and 250 on high side. I began adding some ...

Refrigerant Pressure Temperature Chart - PT Chart for R-410A, R-134A, and R-22. These are currently the three most widely used refrigerants on the market today for HVAC applications in residential and commercial use. R-22 refrigerant is the king and used widely in the residential and commercial markets followed by R-134A which is used in ...An R-22 Replacement for New ACs and Heat Pumps. Freon™ 410A (R-410A) refrigerant offers higher cooling capacity and significantly higher pressure than R-22 for use in systems specifically designed for R-410A. This hydrofluorocarbon (HFC) refrigerant is compatible with polyolefin (POE) oils and replaces R-22 in positive displacement air ...R-410A HFC 72.6-61 691.8 158.3 34.5 67.74 0.261 116.8 0.3948 0.1953 0 2088 A1 0.2 Refrigerant Reference Guide 43 5th Edition 2010 R-410A Technical Guidelines Applications: Air conditioning equipment and heat pumps. Only for newly manufactured equipment, not for retrofitting R-22 systems Performance: Presures are 60% higher than R-22, therefore ...You can pressurize a system to 150 psig with refrigerant and use an electronic leak detector locate the general area of any leaks, then a bubble solution to pin point the leak. That is how it is properly done. Some systems allow higher than 150 psig test pressures, if so, its stamped on the name plate of the system.Pressure (psig) Temp (°C) Liquid Vapor Liquid Vapor Liquid Vapor Liquid Vapor ... R410A PRESSURE TEMPERATURE CHART. Created Date: 7/7/2022 4:49:31 PM ...4 Using Table 2, select the column which is closest to the measured vapor pressure. 5 Scroll down the column to find your calculated superheat. 6 Read the required vapor line temperature at the intersection. (°F) If the measured vapor line temperature does not agree with the required vapor line. 7 temperature, add refrigerant to lower ...

18 Oct 2018 ... ... running at 100 ... Both older R-22 and R-134 operate at lower pressures than R-410A. ... Below this table of example refrigerant operating pressures ...The pressure of R-410A is so high that if your hand gets in the way of a leak, it could cut a finger off. This is a myth, as well as a physical impossibility. Devices such as insulin jet injectors require 7,000 to 10,000 psi pressures to puncture the skin and 16,000 to 25,000 psi pressure spikes are normally used.To use a 410a PT chart, you need to measure the temperature and pressure of the refrigerant at different points in the system, such as the evaporator, condenser, compressor, and metering device. Then, you can compare these values with the corresponding values on the 410a PT chart to determine the state and condition of the refrigerant.™ 410A Refrigerant (R-410A) Piping Guide for Freon™ 410A (ENG Units) Technical Information Suction Line Size—Evaporator to Compressor ... (62 through 38 psig) Suggested Allowable Pressure Drop in psig = 2 °F 4.6 lb (2 °F) 3.5 lb (2 °F) 2.5 lb (2 °F) Equivalent Suction Line Length—Feet System Capacity Btu/Hr System Capacity Tons/Hr ...

Mark paliotta.

The standing pressures on a 410a system will be between 200-240pso usually. This is going to vary a little based on ambient temp and the amount of refrigerant in the system. This is with the system off, for clarification. ... I have a GE frige that was running all the time and not staying cool. I took the back of the freezer off and saw that ...For example, if the HVAC system contains R-410a refrigerant, use the manifold gauges that you only use on R-410a systems to prevent contamination. Turn the thermostat to cool and set the target temperature at least 10 degrees lower than the indoor temperature. Let the system operate for at least 10 minutes to let pressures equalize.During air conditioning mode, the pressure on the vapor line of an R-410A system will be somewhere between 102 to 145 PSIG. If the system had R-22, the vapor pressure would be between 58 to 85 PSIG but these pressures will be dependent on the wet bulb temperature inside the building and the ambient temperature outside the building.R410a freon replacement costs around $260, on average, and most homeowners pay between $140 and $380, depending on the quantity and location. R -410A refrigerant costs anywhere from about $140 to $380 per 25-pound container. Costs rise in the summer when the demand for indoor cooling surges. To replace R-410A refrigerant, …Typical Low Side Pressure Range for R410A in the field: 115-120 psi. Typical High Side Pressure Range for R410A in the field: 410-420 psi. By 2025, high Global Warming Potential (GWP) refrigerants with a GWP of over 750, will be banned together with the systems using that gas. R410A has a GWP > 2,000.

Still though... something doesn't sit well with me about all of it. I think I'm going to change the switch for good measure and reclaim/meter in the charge again. According to my PT chart, the static pressure of R410A at 65° is 185psi. I'm guessing that's not what you were asking about, but that's what it is.r410a running pressure chart. Free Printable 410A PT Chart Templates [PDF] High Altitude Calculator. ... What is the suction pressure of R410A in a Mitsubishi ton split A/C? Quora. Practice Checking the Charge of an R-410A Air Conditioner with Subcooling Method! Scenarios!November 2, 2003. Several major manufacturers are producing comfort air conditioning equipment using refrigerant 410A. The trend towards the use of R-410A continues to grow and there is a demand for technicians who are comfortable working with this higher-pressure replacement for refrigerant 22. Due to the differences between R-22 and the newer ...™ 410A Refrigerant (R-410A) Piping Guide for Freon™ 410A (ENG Units) Technical Information Suction Line Size—Evaporator to Compressor ... (62 through 38 psig) Suggested Allowable Pressure Drop in psig = 2 °F 4.6 lb (2 °F) 3.5 lb (2 °F) 2.5 lb (2 °F) Equivalent Suction Line Length—Feet System Capacity Btu/Hr System Capacity Tons/Hr ...1 Mar 2022 ... If it is more than this, it is considered high. This will also depend on the weather and other conditions.Btenaircool Services January 03, 2018 No comments. R-22. Standing pressure - 150 PSI. Saction pressure - 60 TO 70 PSI. Discharge pressure - 250 TO 300. R-410A. Standing pressure - 260 PSI. Saction pressure - 120 TO 130 PSI. Discharge pressure - 450 TO 500.What is the higher pressure of R-410A? Normally R-22 operating system typically have a high-side (discharge) pressure of 260 psig and low-side (suction) pressure of 76 psig, while a normally R-410A operating system have a high-side (discharge) pressure of 418 psig and low-side (suction) pressure of 130 psig at 45°F/7.2℃. Both older R-22 and R-134 operate at lower pressures than R-410A. R22 Refrigerant Pressure Rules of Thumb Typical Off, Low, High side R22 Pressures & Temperatures. On a properly-charged and working air conditioning system using R-22 refrigerant. Low pressure refrigerant switches on Carrier HVACR typically open at 50 psi and close at 100 psi. This is where our friend R-410A came into play. New machines from 2010 and onwards were banned from using R-22. Instead, they were outfitted with R-410A. If you would like to read more about R-410A refrigerant please have a look at our Puron fact sheet. R-410A PT Chart. Let’s take a look at our pressure table for R-410A Puron.Btenaircool Services January 03, 2018 No comments. R-22. Standing pressure - 150 PSI. Saction pressure - 60 TO 70 PSI. Discharge pressure - 250 TO 300. R-410A. Standing pressure - 260 PSI. Saction pressure - 120 TO 130 PSI. Discharge pressure - 450 TO 500.The typical 410a pressures on a 95 degree day are as follows; Liquid pressure: 296.4 psi. Vapor pressure: 295.5 psi. See all other pressures for R410 on different temperatures of the day from -49°F to 150°F below.When heat is called suction and discharge pressures reach 300 + psi Compressor is running. Show More. Show Less. Ask Your Own HVAC Question. ... So, I decided too and some 410a. The pressures before energizing the unit were 170 lbs. on both sides. Upon energizing the unit the operating pressures were 75lbs on suction side and 250 on high side ...

R-410A condensation heat transfer and pressure drop data are provided for a 7.0 mm O.D. microfin tube at low mass fluxes (50-250 kg/m2 s). The heat transfer coefficient of the microfin tube shows a minimum behavior with the mass flux. At a low mass flux, where flow pattern is stratified, condensation induced by surface tension by microfins overwhelms condensation induced by shear, and the ...

The port sizes for R410A and R22 TXV's are basically identical, so they would each have the same flow capacity with either refrigerant . The difference is a R410A TXV will work properly with R22 only if you change out the R401A powerhead to one for R22. It'll then actually control superheat. The Educational Forums.How to check your AC freon level/pressures. In this video I explain the gauge set, how to put on your gauges, how to read the refrigerant pressures, and how ...1. Optimal Cooling. When the low side pressure operates within the recommended range for 410a, your system can efficiently absorb heat from your indoor environment. Any deviation from this range might compromise the cooling efficiency, leaving certain areas less cooled than others. 2.R22 changes from a liquid to a gas in the evaporator coils of the air handler. Normal temperatures: With compressor running and as reference, on a 90 degree F. day: - Goodman runs 45degrees F on low pressure side and 115degrees F on high pressure side. - 2 ton York runs 40degrees F on low pressure side and 110degrees F on high pressure side.A compressor that uses R-410A refrigerant has more pressure pushing through the tubes of the system than the R-22 compressor. Approximately 60 percent more pressure is required for the refrigerant to cool the air that flows through the ducts or vents of the air conditioning system. So much pressure will cause a R-22 compressor to burst the ...If the air conditioning isn't blowing cold air and the low side pressure is too high, it could be caused by issues with the condenser fan. However, there's also the possibility that the system has been overcharged with too much refrigerant. 1. Defective Condenser Fan. When the fan becomes damaged, airflow through the condenser is diminished.FAQs about refrigerant pressures & charge quantity for air conditioners & heat pumps. This air conditioning repair article series discusses the the diagnosis and correction of abnormal air conditioner refrigerant line pressures as a means for evaluating the condition of the air conditioner compressor motor, which in turn, is a step in how we evaluate and correct lost or reduced air conditioner ...00:00 - What are normal pressures for R410A?00:37 - Can you pump down a 410A system?01:04 - What should my gauges read on 410A?01:39 - Can you put R22 in a R...7 Sept 2018 ... R-22 and R-410A Operating Pressures on Air Conditioners! Checking ... What Should my AC Pressures Be for R410A Refrigerant. Benjamin Sahlstrom ...*Red Italics Indicate Inches of Mercury Below Atmospheric Pressure Saturation Pressure-Temperature Data for R407C (psig)* Temp (°F) Pressure Temp (°C) Temp (°F) Pressure Temp (°C) Temp (°F) Pressure Temp (°C) Created Date: 12/31/2018 2:19:45 PM ...

How to factory reset a honeywell thermostat.

Prosper isd 2024 25 calendar teacher.

Learn how to use a pressure-temperature wall chart, pocket chart, or SMART Pro/R app. We will illustrate how pressure and temperature measurements from a ref...With 75 indoor you should be running approximately 190 on the low side. The correct way to charge the unit would have been to weigh the charge in and in the cooling mode. So if you have 190 suction I would leave it as is and return when it is warm (70) outside to adjust the charge. Bart Jay. 655 Satisfied Customers.Mini split manufacturers have been saying that since befrore R410A came out. All the old R22 units told you to weigh in charge only. And nobody is going to do that. It's like an quick change oil place telling customers that their engines have to be pulled and weighed to check their oil levels. No, its not the same. In this HVAC Training Video, I show the Step By Step Procedure for Charging R-410A Refrigerant into an Air Conditioner that is Low on Refrigerant. I show the... Refrigerant Type R-410A R-410A R-410A R-410A R-410A R-410A R-410A Refrigerant Charge (limit) lbs 13 13 13 17 17 17 17 Oil Type Trane OIL00079 (qt)/OIL00080 (gal) Oil Charge oz 101 101 101 88 112 112 112 ... Low Pressure Gauge Port - Schrader in 0.25 0.25 0.25 0.25 0.25 0.25 0.25Aug 5, 2023 · Read also: R410a Pressure Chart High and Low Side. psi: Pound per square inch, unit of pressure. FAQ What is the normal suction pressure on a 404a walk in the freezer? The normal suction pressure on a 404 a walk in freezer is around 10-20 psig (10 is ideal) on the suction side if working properly. And the high side is about 180 or so. Now here is my question. I have been a hvac maintenance tech for several years now and still learning. Just recently have been working on a 410a system and want to pressure test with nitrogen. It's a Icp heat pump with a hard shut off TXV. I seen a YouTube video with a tech "flowing nitrogen in the low side and reading system pressure on the highBecause R-410A can absorb and release more heat than R-22, your air conditioning compressor can run cooler, reducing the risk of compressor burnout due to overheating. R-410A also functions at a higher pressure than R-22, so new compressors are built to withstand greater stresses, reducing the chance for cracking. ….

This is where our friend R-410A came into play. New machines from 2010 and onwards were banned from using R-22. Instead, they were outfitted with R-410A. If you would like to read more about R-410A refrigerant please have a look at our Puron fact sheet. R-410A PT Chart. Let’s take a look at our pressure table for R-410A Puron.19 Jul 2021 ... R-22 and R-410A Operating Pressures on Air Conditioners! Checking ... AC Most Use Refrigerants R32,R134a,R410a pressure Standing, Running Details.With that said, scientists say that the R-410A refrigerant has a GWP of 2,088. This means that it has an Earth-warming effect of 2,088 times more than CO2. By contrast, R-32 has a GWP value of 675. That's still high, but that also means its GWP is only a third of R-410A. Therefore, R-32 is a greener, eco-friendlier option than R410-A.Carrier model 50 gl-36 321 410a freon Low side pressure 125 psi High side pressure. 490psi Replaced the filter dryer and the piston flush with nitrogen vacumm the system Reacharge again With new freon …5 Jun 2021 ... R22 and R410A Refrigerant Operating Pressures on Air Conditioning Units! ... Checking the Refrigerant Charge on a Running R-410A Inverter MINI ...pressures and refrigeration capacity than R-22. The compositions of Freon™ 407C and Freon™ 410A are as follows: HFC-32 HFC-125 HFC-134a Freon™ 407C (R-407C), wt% 23 25 52 Freon™ 410A (R-410A), wt% 50 50 — Because Freon™ 407C and Freon™ 410A are mixtures of HFCs, they have zero ODP. Table 1 lists the chemical names and formulae of theWe would like to show you a description here but the site won't allow us.View and Download Rheem R-410A installation instructions manual online. PRL-JEC Series two-stage heat pump outdoor units. R-410A heat pump pdf manual download. Also for: Prl-jec series, 024jec, 036jec, 048jec, 060jec.One such substitute that has gained widespread acceptance is R410A, a hydrofluorocarbon (HFC) blend. Unlike R22, R410A does not contribute to ozone depletion and has a lower GWP. This makes it an attractive choice for manufacturers who want to comply with environmental regulations while maintaining the efficiency and performance of HVAC systems.The pressures were still at the 130 on suction side and 335 on the high side, but the cooling has gone away, suction side does not get cool. It has a metering orifice, no txv So, I thought I may be overcharged, since the liquid got in. I reclaimed some 410a (not measured) which sent the pressure too 150 on suction side and 365 on high side ... Running pressures for 410a, R410A Pressure Temperature Chart 14 12.23 11.22 162.63 12.19 11.18 162.05 16 12.95 11.93 173.03 12.91 11.89 172.43 18 13.70 12.68 183.89 13.65 12.64 183.25, I would think we could have a thermostat that could do this: Heating mode: outside temp >65F: Run AUX only - lock out compressor (avoid high pressure) outside temp >10F and <65F: Run compressor and AUX as needed. outside temp <10F: Run AUX only - lock out compressor (avoid defrost cycling) Cooling mode: outside temp <60F: lock …, In this HVAC Training Video, I show the Step By Step Procedure for Charging R-410A Refrigerant into an Air Conditioner that is Low on Refrigerant. I show the..., Make your job easier with our handy refrigerant pressure temperature HVAC app with R-410A included., Suction Pressure/EVAP DTD Rule of Thumb Another common old-school rule of thumb is that suction pressure should be close to the outdoor temperature in an R22 system. However, this rule of thumb (obviously) does not work on an R-410A system. A more applicable guideline is 20°-25° suction saturation below outdoor ambient., R-410A refrigerant is a blend of hydrofluorocarbon (HFC) compounds R-32 and R-125. It has been used as a replacement for R-22 (commonly known as Freon). ... Because R-410A operates at such high pressures, there is an increased risk of an environmentally harmful refrigerant leak during maintenance and repair work. The R-410A phase-out means new ..., Outdoor ambient temperature. Typical low pressure or suction side pressure for R410A is about 120 psi,varying by ambient temperature,here assuming 75°F,may vary by equipment and metering controls. Typical high side pressure for R410A is < 600 psi at an ambient outdoor temperature of 95 °F,may vary by equipment., Let’s take a very efficient 3-ton 20 SEER AC unit that runs on R-22 refrigerant. ... (via pressure and referencing R-410A PT chart) and the thermometer tells us that the subcooled R-410A liquid temperature is 87°F. Let’s calculate R-410A subcooling: Subcooling (R-410A) = 95°F – 87°F = 8°F. In this system, we have 8°F R-410A ..., Feb 4, 2015 · The high side guage was connected to the liquid line. Static, both guages are 160 psig. When the unit ran, BOTH guages dropped to about 130. The high side was perhaps 2-5 higher. The amp draw at the compressor was 8.6 RLA out of a 22.1 suggest maximum on the equipment sticker. , Refrigerant Pressure-Temperature Home Back. Choose Refrigerant: R-410A R-22 °C °F: Psig-40-39-38-37-36 ..., Moreover, the operating, running pressures are closer to 165 PSI at the coil. r-410a operating pressure exceeds the limit of r-22. Any presence of foreign substance such as air can cause abnormal pressure rise and may result in explosion or injury. Vapor pressures are typically as follows: 215. service use only r-410a refrigerant and approved ..., R-410A air conditioner and heat pump split system matches of nominal capacity 90,000 and 120,000 Btuh. This guideline ... Proper adjustment means pressure and temperature of the liquid line at the indoor unit must be measured to calculate subcooling at the indoor unit. If subcooling at the, With that said, scientists say that the R-410A refrigerant has a GWP of 2,088. This means that it has an Earth-warming effect of 2,088 times more than CO2. By contrast, R-32 has a GWP value of 675. That's still high, but that also means its GWP is only a third of R-410A. Therefore, R-32 is a greener, eco-friendlier option than R410-A., No, you cannot. To make a short story long, R410A and R22 are refrigerants. They are both good refrigerants and they both work, but they have to be charged in the system at different pressures. R410A is a higher pressure system and R22 is a lower pressure system. Putting them together would be like putting two cats in a box and sending them ..., Constants for vapor pressure of saturated vapor (dew point), p g: A = -1.440004 E+00 E = -3.521484 E+00 B = -6.865265 E+00 F = -7.750000 E+00 C = -5.354309 E-01 X o = 2.086902 E-01 D = -3.749023 E+00 Because both pressure and temperature appear in the reduced form in the equation, the same constants can be used for either SI or ..., No, you cannot. To make a short story long, R410A and R22 are refrigerants. They are both good refrigerants and they both work, but they have to be charged in the system at different pressures. R410A is a higher pressure system and R22 is a lower pressure system. Putting them together would be like putting two cats in a box and sending them ..., What are normal operating pressures for R134a? The normal running pressure of R134A is between 22 and 57 psi. What is the pressure of AC gas? If using AC refrigerant R-22, a 1.5 ton AC should ideally have the pressure between 65 and 70 PSI. For 1 ton AC, the AC gas pressure will be 60 to 65 PSI. What should 410A pressure be at 90 degrees? R ..., If a well is running dry, the water pressure indoors may drop, and water may appear discolored. Use a probe to determine the depth of the water inside the well. Alternatively, Walk..., The technician installs pressure gauges to obtain the system pressures. New air-conditioning systems use R-410A. If the system were standing at 80°F, the system should have 235 psig of pressure, according to the temperature/ pressure chart for R-410A at 80°F. NOTE: Care should be used in the standing pressure comparison., R410A pressure gauges are instruments used to measure the pressure of the R410A refrigerant inside an air conditioning system. These gauges consist of two dials - the low-pressure gauge and the high-pressure gauge. The low-pressure gauge measures the suction or evaporator pressure while the high-pressure gauge measures the discharge or ..., When charging a refrigeration system, there are five main rules to follow: Rule 1. Always charge a receiver/sight glass/TXV system under a high evaporator heat load. This could mean simply opening the doors or putting an artificial or false heat load on the evaporator. Rule 2., Running and maintaining the system will be cost-friendly as the unit doesn’t consume a lot of electricity to cool a space; Since R454B performs better than R410A, it’s a more energy efficient refrigerant. You’ll need a lesser R454B charge within a system than when using R410A. This lowers the cost of running a system with the refrigerant., With R-32, an inverter driven compressor will run more slowly to achieve the same capacity as R-410A, meaning a large drop in power consumption, improving the EER and IEER. We also tested R-454B the same way and found it needed higher compressor speeds to get to full load capacities, and that follows its expected thermodynamic …, when the discharge-to-suction pressure differential exceeds 550 to 625 psid (38-43 bar). When the valve opens, hot discharge gas is routed back into the area of the motor overload to cause a trip. During fan failure testing, system behavior and operating pressures will depend on the type of refrigerant metering device., AC compressors made to use R-410A are therefore able to withstand more stress without the likelihood of cracking. That is why if you were to put R-410A in an R-22 AC unit the system would just rupture due to the high pressure. Recharging/Top Off. Most people are familiar with the process involved when an air conditioner running on R-22 leaks., psig °f psig °f psig °f psig °f psig °f 12; -37.7. 114, discharged pressure are 40% to 70% greater than R-22 and the discharge temperature of R-410A is lower due to its higher vapor heat capacity. Never heat an R-410A cylinder over 125ºF. • The high-pressure switch will open at 610 psig (plus or minus 10 psig), and close at 500 psig (plus or minus 15 psig). The low pressure control will open, Minimum order 250. 2. Bulk Pack Only. 50 per box. Minimum order 100. 3. R-410A compatibility offered with P266SNR-2C transducer. PRODUCT SWITCH ACTION BOTTOM OF RANGE TOP OF RANGE MAXIMUM WORKING PRESSURE TYPICAL APPLICATIONS. P70 SERIES ADJUSTABLE ON/OFF PRESSURE CONTROLS. P70AA-2CSPST Open Low 0 150 325 Suction pressure control — loss of ..., 00:00 - What are normal pressures for R410A?00:37 - Can you pump down a 410A system?01:04 - What should my gauges read on 410A?01:39 - Can you put R22 in a R..., With 410a heat pumps is there a recommended suction pressure. For example with R22 air-con systems I always aim for 400 suction and 1500 discharge and similar with 407c systems. I have been told to aim for round the 100 psi/700kpa mark with is about 0 degree C Was just curious for fault finding purposes. Cheers in advance, chris., Aug 5, 2023 · Read also: R410a Pressure Chart High and Low Side. psi: Pound per square inch, unit of pressure. FAQ What is the normal suction pressure on a 404a walk in the freezer? The normal suction pressure on a 404 a walk in freezer is around 10-20 psig (10 is ideal) on the suction side if working properly. And the high side is about 180 or so. , Discharge line temperature 150°F (65°C) or higher at the end of the freeze cycle. Discharge line temperature less than 150°F (65°C) at the end of the freeze cycle or Compressor shell is frosted. Evaporator Outlet Temperature Comparison. Attach and insulate temperature probes between evaporator outlet and 90° elbow., ™ 410A Refrigerant (R-410A) 0 0 20 40 60 80 Temperature (°F) 100 120 140 R-22 R-410A 100 200 300 400 500 600 700 Product Information Freon™ 410A is a non-ozone depleting high efficiency hydrofluorocarbon (HFC) refrigerant. Freon™ 410A has higher cooling capacity and operating pressures than R-22 for new equipment specifically designed ...